Power Infrastructure · HardwareFinancial Services Firm · Financial Services · 2024

UPS & Enterprise Hardware

Zero downtime through 47 power events since deployment.

UPSPower InfrastructureATSServer RoomHardwareMonitoring
Scroll to explore

The challenge

Complex constraints.Real-world pressure.

Before architecture and implementation, we mapped every operational blocker and business risk. These were the core constraints shaping the entire solution design.

4 critical challenges
01Constraint

3 data-loss incidents in 18 months

02Constraint

No power monitoring on the server room

03Constraint

Single-point UPS protecting critical servers

04Constraint

Generators with no automatic failover

What we built

A system built for the problem, not off the shelf.

We conducted a full power infrastructure audit: measuring server room load, identifying single points of failure, and testing the existing UPS runtime under actual load conditions. The audit confirmed the UPS batteries had degraded to 38% of rated capacity.

The replacement design specified a redundant online UPS configuration (N+1) with new battery banks sized for 30 minutes at full load, a static bypass switch, and an automatic transfer switch (ATS) for the generator with a sub-3-second failover time.

A dedicated power management system was installed, monitoring UPS health, battery state of charge, input and output voltages, and load percentage — with alerts to the operations team and to on-call engineering if any parameter crossed a threshold.

Capabilities delivered

Every feature with a reason.

01

N+1 redundant UPS configuration

Dual online UPS units in parallel with automatic failover. N+1 design ensures continuity if one unit requires maintenance.

02

Automatic transfer switch (ATS)

Sub-3-second automatic generator failover on mains failure. Tested monthly. Eliminates the 12-minute manual window.

03

Power management monitoring

Real-time UPS health, battery capacity, input/output quality, and load percentage. Alerting on threshold breach.

04

Power conditioning & surge suppression

Voltage regulation and surge suppression on all critical circuits. Protects against brownouts, spikes, and harmonics.

05

Battery management system

Automated battery health testing, temperature monitoring, and capacity estimation. Alerts on degradation before failure.

06

Full infrastructure documentation

Single-line diagrams, test reports, UPS configuration files, and maintenance schedules delivered at handover.

Measured outcomes

Numbers that changed how they operate.

Zero in 12 months
Unplanned downtime events
0
Power events absorbed
0min → 2.8 sec
Generator failover time
0/year → 0
Data-loss incidents